TRAINING: PEG TEST

Place two level rods approximately 200 feet apart.
Setup the instrument at the midpoint of the two rods and read each rod.


Record the readings and note the exact difference.
Move the instrument closer to either road and, again, read each rod.

Record the readings and note the exact difference.
If the read difference doesn’t match, the instrument needs service.